APP Monitor
Powerful and Reliable 5~10 Years Service Life
Environmental Friendly
Built-in Safety ProtectionIntelligent Bluetooth
BMS Support Parellels
Technical Specifications
|
||||
50AH
|
100AH
|
120AH
|
150AH
|
200AH
|
Nominal Voltage
|
12.8 V/25.6V
|
Recommended Charge Current
|
50 A
|
|
Nominal Capacity
|
200 AH @ 0.2C
|
Max. Charge Current
|
100 A
|
|
Energy
|
5120 Wh
|
Max. Continuous Discharge Current
|
100 A
|
|
Internal Resistance(AC)
|
30 mΩ
|
Peak Discharge Current
|
200 A (3S)
|
|
Cycle Life
|
6000+ Cycles @ 1C 100% DOD
|
BMS Discharge Cut-off Voltage
|
10 V
|
|
Monthly Self Discharge
|
Less than 2%
|
Charge Temperature
|
0~45 ℃
|
|
Efficiency of Charge
|
100% @ 0.5 C
|
Discharge Temperature
|
-20℃ to 60 ℃
|
|
Efficiency of Discharge
|
96~99% @1 C
|
Storage Temperature
|
-20℃ to 60 ℃
|
|
Charge Voltage
|
14.6 ± 0.2 V
|
IP Class
|
IP65
|
|
Charge Model
|
0.2C to 14.6 V , then 14.6 V , charge current to 0.02C
|
Maximum Modules in Series/parallels
|
4S or 4P
|